Draining the Unit
When the portable air conditioner is in cooling mode, or dehumidify
mode, it will remove moisture from the air. The condensed water
from the air will be collected in an internal reservoir and will be
evaporated and exhausted out of the exhaust hose. However, in
very humid conditions, the internal reservoir may fill completely.
This causes the air conditioner to turn off to avoid overflowing the
internal reservoir. When water tank is full a buzzer will sound eight
times and on the LED window will display error code “H8”.
Direct drainage
1. Remove the rubber drain plug from the drain port.
2. Connect a drain hose to the drain port.
The portable air conditioner will now drain through the drain hose.
Please note that this unit has no drain pump; all water will drain
with gravity only, i.e., only “downhill.”
2
Attach the drain hose clamp to the
back panel of the air conditioner
near the drain port with the screw.
Attach one end of the drain hose
to the drain port with the clip
provided.
3
Insert the rubber plug into the
other end of the drain hose and
secure clip provided.