Wall installation (permanent mounting) Key for the above diagram: 1. Exhaust port 2. Vent connector 3. Exhaust hose 4. Round adapter 1. Drill
Notes: 1. The exhaust hose supplied with the portable air conditioner can be extended from 14 1/2” to 59”. However, the shorter the hose, the more ef
Control panel LED indicators 1. “ST” = Set Temperature When this light is lit (when the TEMP. UP or TEMP. DOWN buttons are pressed), the LED d
If this light is flashing, the internal condensate tank is full and the unit has shut itself off. Empty the tank to restart the unit. See the Drainage
Remove the batteries from the remote control if you are not going to use it for several weeks or more. Caution: Do not abuse the remote control. Do n
1.5°F per hour, for two hours. In Heating mode, the Sleep function lowers the thermostat’s temperature setting by 1.5°F per hour, for two hours. This
Regulating airflow direction To adjust airflow, the louvers on this portable air conditioner can be adjusted up and down and from right to left. To a
Manual drainage When the portable air conditioner is in cooling or dry mode, it will dehumidify the air. The water dehumidified from the air will be
5. Empty the drain tray. 6. Repeat steps 1-5 as necessary. Direct drainage 1. Remove the drain cap and rubber plug from the drain. 2. Connect the
Installing the charcoal filter 1. Grasp the filter frame (it slides in and out of the top back of the portable air conditioner) and pull up until it
Table of contents Table of contents 1 Thank you 2 Energy saving tips 2 Notes 2 Specifications 3 Safety precautions 3 Parts 5
Troubleshooting If the portable air conditioner is not working properly, it is usually due to a minor problem that the user can handle. Before calling
The air intake or exhaust ports are partially obstructed. Remove the obstruction. The condenser coils are dirty Vacuum the air inlet located on the s
"E5" shows in the LED display. The overheating protection sensor has detected a fault. Contact customer service. "E7" shows in th
22All products and components replaced by EdgeStar under warranty service become the property of EdgeStar. OBTAINING WARRANTY SERVICE: Contact Edge
Thank you Thank you for purchasing an EdgeStar portable air conditioner. Rest assured that all EdgeStar products are designed and manufactured to the
Specifications Model AP410HS Maximum Room Size (cooling)* 400 ft² Maximum Room Size (heating)* 400 ft² Power consumption for cooling mode 1150W Pow
6. This portable air conditioner has been designed for residential use. 7. Always turn the portable air conditioner off before unplugging it. 8. Do
Parts Front view 1. Control panel 2. Adjustable louvers 3. Carry handles 4. Caster wheels Rear view 1. Air inlet 2. Exhaust port 3. Power co
Accessories Owner’s manual and warranty card Drain hose Exhaust hose Rectangular vent connector Round adapter Drain tray Carbon filter Cap for round
Installation Installing the exhaust hose In order to be used effectively, the exhaust hose must be mounted to the back of the unit. 1. Make sure
Window installation This portable air conditioner ships with a plastic window kit for temporary mounting in standard windows. The plastic window kit